  1. Akesson, T; Baker, K; Bondarenko, V; Bytchkov, V; Carling, H; Danielsson, H; Dittus, F; Dolgoshein, B; Dressnandt, N; Ebenstein, W; Eerola, P; Egede, U; Farthouat, P; Froidevaux, D; Gavrilenko, I; Grichkevitch, Y; Hajduk, Z; Hanson, G; Ivochkin, V; Jagielski, S; Keener, P; Konovalov, S; Kekelidze, G; Kramarenko, V; Laritchev, A; Lichard, P; Lundberg, B; Luehring, F; McFarlane, K; Muraviev, S; Nadtochy, A; Nevski, P; Newcomer, F; Ogren, H; Oh, S; Peshekhonov, V; Romaniouk, A; Rust, D; Schegelsky, V; Semenov, S; Shmeleva, A; Smirnov, S; Smirnova, L; Sosnovtsev, V; Spiridenkov, E; Stavrianakou, M; Thulesius, M; Tikhomirov, V; Van Berg, R; Wang, C; Williams, H, Tracking performance of the transition radiation tracker prototype for the ATLAS experiment, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 485 no. 3 (June, 2002), pp. 298-310 [doi] .

    Abstract:
    A prototype of the Transition Radiation Tracker (TRT) for the ATLAS experiment at the CERN LHC has been built and tested at the CERN SPS. Detailed studies of the drift-time measurements, alignment technique, hit registration efficiency, track and momentum accuracy were performed. A coordinate measurement accuracy of 150 μm for a single TRT drift tube and momentum resolution of 0.8% for 20 GeV pions in a 1.56 T magnetic field were achieved. The results obtained are in agreement with the expected tracking performance of the ATLAS TRT. © 2001 Published by Elsevier Science B.V.