publications by Robert A. Malkin.
Papers Published
- Malkin, R.A. and Dongxu Guan and Wikswo, J.P., Experimental evidence of improved transthoracic defibrillation with electroporation-enhancing pulses,
IEEE Trans. Biomed. Eng. (USA), vol. 53 no. 10
(2006),
pp. 1901 - 10 [TBME.2006.881787] [abs].
- Dolan, Jennifer M. and Testa, Diane Muratore and Malkin, Robert A., Design of a bilirubin light intensity tester for developing world hospitals,
Bioengineering, Proceedings of the Northeast Conference, vol. 2006
(2006),
pp. 47 - 48 [abs].
- Malkin, R.A. and Jackson, S.R. and Nguyen, J. and Zhao Yang and Dongxu Guan, Experimental verification of theoretical predictions concerning the optimum defibrillation waveform,
IEEE Trans. Biomed. Eng. (USA), vol. 53 no. 8
(2006),
pp. 1492 - 8 [TBME.2006.876643] [abs].
- Malkin, R.A. and Jackson, S.R. and Nguyen, J. and Zhao Yang and Dongxu Guan, Reply to "On the optimal defibrillation waveform-how to reconcile theory and experiment?",
IEEE Trans. Biomed. Eng. (USA), vol. 53 no. 8
(2006),
pp. 1726 - 7 [TBME.2006.878554] [abs].
- Hoffmeister, B.K. and Shores, A.R. and Banerjee, S. and Malkin, R.A., Effect of electrically insulating materials on magnetically induced electrical currents in a tissue-like medium,
Am. J. Phys. (USA), vol. 74 no. 4
(2006),
pp. 260 - 6 [1.2151211] [abs].
- Deni, H. and Muratore, D.M. and Malkin, R.A., Development of a pulse oximeter analyzer for the developing world,
2005 IEEE 31st Annual Northeast Bioengineering Conference (IEEE Cat. No. 05CH37674)
(2005),
pp. 227 - 8 [abs].
- Malkin, R.A. and Kramer, N. and Schnitz, B. and Gopalakrishnan, M. and Curry, A.L., Advances in electrical and mechanical cardiac mapping,
Physiol. Meas. (UK), vol. 26 no. 1
(2005),
pp. 1 - 14 [R01] [abs].
- Schnitz, B.A. and Dong Xu Guan and Malkin, R.A., Design of an integrated sensor for in vivo simultaneous electrocontractile cardiac mapping,
IEEE Trans. Biomed. Eng. (USA), vol. 51 no. 2
(2004),
pp. 355 - 61 [TBME.2003.820388] [abs].
- Malkin, R.A. and de Jongh Curry, A., Frequency dependence of the cardiac threshold to alternating current between 10 Hz and 160 Hz,
Med. Biol. Eng. Comput. (UK), vol. 41 no. 6
(2003),
pp. 640 - 5 [abs].
- Raphisak, P. and de Jongh Curry, A. and Malkin, R.A. and Schuckers, S.A.C., Heart rate variability in rats with aldosterone-induced chronic heart failure,
Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439), vol. Vol.1
(2003),
pp. 228 - 31 [IEMBS.2003.1279584] [abs].
- Hoffmeister, B.K. and Sexton, J.A. and Sheals, B.S. and de Jongh, A.L. and Malkin, R.A., Mechanical response of the left ventricle during AC induced hemodynamic collapse,
Computers in Cardiology 2002. Volume 29 (Cat. No.02CH37421)
(2002),
pp. 701 - 3 [CIC.2002.1166869] [abs].
- Hoffmeister, B.K. and Sheals, B.S. and de Jongh, A.L. and Malkin, R.A., Ventricular wall thickness and volume during hemodynamic collapse produced by AC leakage current,
Conference Proceedings. Second Joint EMBS-BMES Conference 2002. 24th Annual International Conference of the Engineering in Medicine and Biology Society. Annual Fall Meeting of the Biomedical Engineering Society (Cat. No.02CH37392), vol. vol.2
(2002),
pp. 1461 vol.2 - [IEMBS.2002.1106483] [abs].
- Patel, S. and Malkin, R.A., The response of intact guinea pigs to AC leakage currents,
Computers in Cardiology 2002. Volume 29 (Cat. No.02CH37421)
(2002),
pp. 729 - 31 [CIC.2002.1166876] [abs].
- Kramer, N.R. and Schnitz, B.A. and Malkin, R.A., Design of an integrated sensor for in-vivo simultaneous electrocontractile cardiac mapping,
Conference Proceedings. Second Joint EMBS-BMES Conference 2002. 24th Annual International Conference of the Engineering in Medicine and Biology Society. Annual Fall Meeting of the Biomedical Engineering Society (Cat. No.02CH37392), vol. vol.2
(2002),
pp. 1724 - 5 [IEMBS.2002.1106621] [abs].
- de Jongh, A.L. and Sheals, B.S. and Chau, D.K. and Hoffmeister, B.K. and Malkin, R.A., Left ventricular volume changes after defibrillation,
Conference Proceedings. Second Joint EMBS-BMES Conference 2002. 24th Annual International Conference of the Engineering in Medicine and Biology Society. Annual Fall Meeting of the Biomedical Engineering Society (Cat. No.02CH37392), vol. vol.2
(2002),
pp. 1438 vol.2 - [IEMBS.2002.1106470] [abs].
- Malkin, R.A. and Kiani, M., The Engineering World Health Summer Institute: a new educational opportunity,
Conference Proceedings. Second Joint EMBS-BMES Conference 2002. 24th Annual International Conference of the Engineering in Medicine and Biology Society. Annual Fall Meeting of the Biomedical Engineering Society (Cat. No.02CH37392), vol. vol.3
(2002),
pp. 2636 vol.3 - [IEMBS.2002.1053465] [abs].
- Malkin, Robert A. and Malik, M. and Gopalakrishnan, M., Effect of 2,3 butanedione monoxime(BDM) on ventricular fibrillation,
Computers in Cardiology, vol. 29
(2002),
pp. 733 - 734 [abs].
- Eason, J. and Gades, N.M. and Malkin, R.A., A novel ultrasound technique to estimate right ventricular geometry during fibrillation,
Physiol. Meas. (UK), vol. 23 no. 2
(2002),
pp. 269 - 78 [303] [abs].
- Malkin, R.A., Large sample test of defibrillation waveform sensitivity,
J. Cardiovasc. Electrophysiol. (USA), vol. 13 no. 4
(2002),
pp. 361 - 70 [x] [abs].
- Vigmond, E.J. and Trayanova, N.A. and Malkin, R.A., Excitation of a cardiac muscle fiber by extracellularly applied sinusoidal current,
J. Cardiovasc. Electrophysiol. (USA), vol. 12 no. 10
(2001),
pp. 1145 - 53 [x] [abs].
- Malkin, R.A. and Hoffmeister, B.K., Mechanisms by which AC leakage currents cause complete hemodynamic collapse without inducing fibrillation,
J. Cardiovasc. Electrophysiol. (USA), vol. 12 no. 10
(2001),
pp. 1154 - 61 [x] [abs].
- Malkin, R.A., Can an RC membrane model predict the efficacy of a defibrillation waveform: an analysis of defibrillation mechanisms in 140 defibrillation waveforms,
Computers in Cardiology 2001. Vol.28 (Cat. No.01CH37287)
(2001),
pp. 243 - 4 [CIC.2001.977637] [abs].
- Barros, A.K. and McLaughlin, J.E. and Ohnishi, N. and Malkin, R.A., Analysis of mice heart rate variability obtained through plethysmograph power spectrum,
Computers in Cardiology 2001. Vol.28 (Cat. No.01CH37287)
(2001),
pp. 661 - 2 [CIC.2001.977742] [abs].
- Malkin, R.A. and Smith, S.R. and Hoffmeister, B.K., Defibrillation and the geometry of the heart: a novel measurement with implications for defibrillation mechanisms,
Physiol. Meas. (UK), vol. 22 no. 2
(2001),
pp. 309 - 21 [304] [abs].
- Eason, J.C. and Malkin, R.A., A simulation study evaluating the performance of high-density electrode arrays on myocardial tissue,
IEEE Trans. Biomed. Eng. (USA), vol. 47 no. 7
(2000),
pp. 893 - 901 [10.846683] [abs].
- Malkin, R.A. and Hoffmeister, B.K., The mechanism by which pacing rate affects the upper limit of ventricular vulnerability to fibrillation by T-wave stimulation,
Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. No.99CH37015), vol. vol.1
(1999),
pp. 284 vol.1 - [IEMBS.1999.802357] [abs].
- Malkin, R.A. and Hoffmeister, B.K., AC leakage currents cause complete hemodynamic collapse below the ventricular fibrillation threshold,
Computers in Cardiology 1999. Vol.26 (Cat. No.99CH37004)
(1999),
pp. 351 - 3 [CIC.1999.825979] [abs].
- Rowan, C.A. and Malkin, R.A. and Entcheve, E.G., The effect of critical point location and membrane kinetics on VF induction by T-wave stimulation,
Computers in Cardiology 1998. Vol. 25 (Cat. No.98CH36292)
(1998),
pp. 189 - 92 [CIC.1998.731765] [abs].
- LoSicco, T. and Malkin, R.A., Optical measurement of transmembrane potential in intact cardiac tissues using fluorescent resonance energy transfer,
Computers in Cardiology 1998. Vol. 25 (Cat. No.98CH36292)
(1998),
pp. 573 - 6 [CIC.1998.731930] [abs].
- Malkin, R.A. and Johnson, E.E., The effect of inducing ventricular fibrillation with 50-Hz pacing versus T wave stimulation on the ability to defibrillate,
Pacing Clin. Electrophysiol. (USA), vol. 21 no. 5
(1998),
pp. 1093 - 7 [abs].
- Malkin, R.A., Constructing a multichannel electrocardiography system from a few standardized, high-level components,
IEEE Eng. Med. Biol. Mag. (USA), vol. 17 no. 1
(1998),
pp. 34 - 8 [51.646219] [abs].
- Aguel, F. and Trayanova, N.A. and Eason, J.C. and Siekas, G. and Fishler, M.G. and Malkin, R.A., Impact of endocardial lead position on transvenous defibrillation efficacy: A simulation study,
Computers in Cardiology
(1997),
pp. 85 - 88 [abs].
- Malkin, R.A. and Li, H., Bayesian estimator of the minimum stimulus strength to induce ventricular fibrillation,
Computers in Cardiology
(1997),
pp. 81 - 83 [abs].
- Malkin, R.A., The matched-pairs defibrillation efficacy hypothesis test,
1995 IEEE Engineering in Medicine and Biology 17th Annual Conference and 21 Canadian Medical and Biological Engineering Conference (Cat. No.95CH35746), vol. vol.1
(1997),
pp. 263 - 4 [IEMBS.1995.575101] [abs].
- Aguel, F. and Trayanova, N.A. and Eason, J.C. and Siekas, G. and Fishler, M.G. and Malkin, R.A., Impact of endocardial lead position on transvenous defibrillation efficacy: a simulation study,
Computers in Cardiology 1997. (Cat. No.97CH36184)
(1997),
pp. 85 - 8 [CIC.1997.647836] [abs].
- Li, H. and Malkin, R.A., A scalable and shiftable Bayesian defibrillation efficacy estimator,
Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. `Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136), vol. vol.1
(1997),
pp. 371 - 3 [IEMBS.1997.754553] [abs].
- Malkin, R.A. and Eynard, J.-N. and Pergola, N.F., Extended cardiac tachyarrhythmias in guinea pigs,
Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. `Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136), vol. vol.1
(1997),
pp. 387 - 8 [IEMBS.1997.754558] [abs].
- Compos, A.T. and Malkin, R.A. and Ideker, R.E., An up-down Bayesian, defibrillation efficacy estimator,
Pacing Clin. Electrophysiol. (USA), vol. 20 no. 5
(1997),
pp. 1292 - 300 [abs].
- Hui Li and Malkin, R.A., Estimating myocardial activation times by maximum likelihood estimation,
Computers in Cardiology 1996 (Cat. No.96CH36012)
(1996),
pp. 729 - 32 [CIC.1996.542640] [abs].
- Malkin, R.A. and Entcheva, E., The mechanism of the ULV dose-response curve: a model study,
Computers in Cardiology 1996 (Cat. No.96CH36012)
(1996),
pp. 213 - 16 [CIC.1996.542511] [abs].
- Malkin, R.A. and Pilkington, T.C. and Ideker, R.E., Estimating defibrillation efficacy using combined upper limit of vulnerability and defibrillation testing,
IEEE Trans. Biomed. Eng. (USA), vol. 43 no. 1
(1996),
pp. 69 - 78 [10.477702] [abs].
- Malkin, Robert A., Integration of student presentations into advanced classes,
Journal of Engineering and Applied Science, vol. 2
(1995),
pp. 713 - 715 [abs].
- Malkin, R.A., Integration of student presentations into advanced classes,
Proceedings. Frontiers in Education 1995 25th Annual Conference. Engineering Education for the 21st Century (Cat. No.95CH35867), vol. vol.2
(1995),
pp. 4 - 4 [FIE.1995.483176] [abs].
- Malkin, R.A., Location and characterization of myocardial infarctions using a multielectrode, intracavitary probe,
Computers in Cardiology 1994
(1995),
pp. 145 - 8 [CIC.1994.470228] [abs].
- Malkin, R.A. and Compos, A.T. and Raymond, L.J. and Bernstein, R.C., A Bayesian up-down estimator of the 80% effective defibrillation dose,
Proceedings of the 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Engineering Advances: New Opportunities for Biomedical Engineers (Cat. No.94CH3474-4), vol. vol.1
(1994),
pp. 23 - 4 [IEMBS.1994.412171] [abs].
- Malkin, R.A. and Pilkington, T.C., Defibrillation efficacy estimation using Bayesian estimation theory,
ICASSP-93. 1993 IEEE International Conference on Acoustics, Speech, and Signal Processing (Cat. No.92CH3252-4)
(1993),
pp. 79 - 82 [ICASSP.1993.319059] [abs].
- Malkin, R.A. and Juhlin, S.P. and Penzotti, J.E. and Pilkington, T.C. and Plonsey, R., Optimum detection of myocardial infarctions with an intracavitary probe,
Proceedings. Computers in Cardiology 1993 (Cat. No.93CH3384-5)
(1993),
pp. 5 - 8 [CIC.1993.378518] [abs].
- Juhlin, S.P. and Malkin, R.A. and Penzotti, J.E. and Pilkington, T.C. and Plonsey, R., A generalized electrocardiographic spherical shells model with emphasis on the paced infarcted heart,
Proceedings. Computers in Cardiology 1993 (Cat. No.93CH3384-5)
(1993),
pp. 659 - 62 [CIC.1993.378316] [abs].
- Malkin, R.A. and Burdick, D.S. and Johnson, E.E. and Pilkington, T.C. and Swanson, D.K. and Ideker, R.E., Estimating the 95% effective defibrillation dose,
IEEE Trans. Biomed. Eng. (USA), vol. 40 no. 3
(1993),
pp. 256 - 65 [10.216409] [abs].
- Malkin, R.A. and Alexandrou, D., Acoustic classification of abyssopelagic animals,
IEEE J. Ocean. Eng. (USA), vol. 18 no. 1
(1993),
pp. 63 - 72 [48.211495] [abs].
- Penzotti, J.E. and Malkin, R.A. and Pilkington, T.C., A new high performance designer of optimal defibrillation experiments,
Proceedings of Computer in Cardiology 1992 (Cat. No.92CH3259-9)
(1992),
pp. 487 - 90 [CIC.1992.269519] [abs].
- Malkin, R. A. and Pilkington, T. C. and Johnson, E. E. and Ideker, R. E., Optimum estimation of the 95 percent effective defibrillation dose,
Proceedings of the Annual Conference on Engineering in Medicine and Biology, vol. 13 no. pt 2
(1991),
pp. 758 - 759 [abs].
- Malkin, R. A. and Pilkington, T. C. and Burdick, D. S., Optimizing existing defibrillation thresholding techniques,
Proceedings of the Annual Conference on Engineering in Medicine and Biology no. pt 2
(1990),
pp. 640 - 641 [abs].
- Malkin, R.A. and Penzotti, J.E. and Juhlin, S.P. and Pilkington, T.C. and Plonsey, R., Statistical analysis of signals from an intracavitary probe in a diseased heart,
Med. Biol. Eng. Comput. (UK), vol. 35 no. 5
,
pp. 462 - 6 [abs].