Papers Published
Abstract:
This paper describes the optimization of the distribution of heat transfer (cooling) during the process of gas compression. The coolant is a stream of cold liquid. There is a fundamental tradeoff between the savings in compressor power, which are due to distributed cooling, and the pumping power required to circulate the coolant. The tradeoff is revealed on the basis of a combined model of multi-stage gas compression, resistance to fluid flow, and area-constrained counter- or co-current heat exchange between the gaseous stream and the liquid stream. The results are illustrated for the compressor of an actual ammonia refrigeration plant, for which the distributed-cooling design is highly recommended because the compressor discharge temperature in such units is high. It is shown that there is an optimal coolant (water) flow rate such that the total power requirement is minimized. The optimized distribution of gas compression and cooling is robust with respect to the selection of the water flow rate. © 2005 Elsevier Ltd. All rights reserved.
Keywords:
Compaction;Heat transfer;Optimization;Ammonia;Robustness (control systems);Flow of fluids;
The mission of Duke's Mechanical Engineering and Materials Science educational programs is to provide the knowledge, skills, and credentials needed to be successful in the practice of engineering; the preparation necessary to undertake professional registration; an educational preparation for graduate or professional study; and an education background that is the basis for professional growth and leadership throughout a career that may encompass a broad range of endeavors, both technical and non-technical.