Papers Published

  1. Katz, I.M. and Shaughnessy, E.J., An electronically switched flowmeter and temperature sensor employing a single thermistor probe, J. Phys. E, Sci. Instrum. (UK), vol. 21 no. 1 (1988), pp. 108 - 12 [020] .
    (last updated on 2007/04/06)

    Abstract:
    The design of an electronically switched flowmeter and temperature sensor employing a single thermistor probe is described. Digital temperature compensation is incorporated in the design. The concept is applicable to geophysical flows; in this case, design criteria for a tidal channel were used. The flowmeter is designed for use in the 0.05 to 0.5 m s4-1 range with a fluid temperature variation of 2°C. A frequency response of 0.25 Hz is obtained

    Keywords:
    electric sensing devices;flowmeters;geophysical equipment;probes;thermistors;