- Schwartz, FR; Daubert, MA; Molvin, L; Ramirez-Giraldo, JC; Samei, E; Marin, D; Tailor, TD, Coronary Artery Calcium Evaluation Using New Generation Photon-counting Computed Tomography Yields Lower Radiation Dose Compared With Standard Computed Tomography.,
J Thorac Imaging, vol. 38 no. 1
(January, 2023),
pp. 44-45 [doi] .
(last updated on 2025/05/31)Abstract:
Prospective head-to-head comparison of coronary calcium scores between standard computed tomography (CT) and photon-counting CT show no significant differences, while photon-counting CT administers substantially lower radiation dose.