Abstract:
We report drift-free two-axis tilting MEMS mirrors fabricated from single crystal silicon. These micromirrors survive 1000 G mechanical shocks and exhibit angular stability better than 4 millidegrees under simulated office vibrations. Two hermetically sealed mirror arrays were used to build a low-loss nonblocking 1000x1000-port optical cross-connect switch.