Fitzpatrick Institute for Photonics Fitzpatrick Institute for Photonics
Pratt School of Engineering
Duke University

 HOME > pratt > FIP    Search Help Login pdf version printable version 

Publications [#132001] of James M Provenzale

Papers Published

  1. JD Eastwood, JM Provenzale, LM Hurwitz, TY Lee, Practical injection-rate CT perfusion imaging: deconvolution-derived hemodynamics in a case of stroke., Neuroradiology, Germany, vol. 43 no. 3 (March, 2001), pp. 223-6, ISSN 0028-3940
    (last updated on 2007/02/06)

    Abstract:
    Previously reported methods of dynamic, contrast-enhanced, CT perfusion imaging in acute stroke have been promising but substantially limited by their dependence on very rapid rates of injection (typically 10-20 ml/s in an arm vein). Newly available deconvolution software permits the use of lower rates of injection (e. g., 3-4 ml/s), and rapidly provides maps of cerebral blood flow, cerebral blood volume and mean transit time. We report the potential of CT perfusion imaging performed with an injection rate of 4 ml/s to provide information on the extent of hemodynamic abnormality, and to help distinguish viable from nonviable ischemic tissue. The slower injection rates permitted by deconvolution analysis substantially enhance the practicality of CT perfusion imaging for studying stroke.

    Keywords:
    Brain • Cerebrovascular Accident • Contrast Media • Drug Administration Schedule • Hemodynamic Processes • Humans • Injections, Intravenous • Male • Middle Aged • Regional Blood Flow • Tomography, X-Ray Computed • administration & dosage* • blood supply* • methods* • pathology*