Pratt School of Engineering
 HOME > pratt    Search Help Login 

Publications [#168914] of Mark W. Dewhirst

Papers Published

  1. SL Brady, G Toncheva, MW Dewhirst, TT Yoshizumi, Characterization of a 137Cs irradiator from a new perspective with modern dosimetric tools., Health physics, United States, vol. 97 no. 3 (September, 2009), pp. 195-205, ISSN 1538-5159
    (last updated on 2009/12/31)

    Abstract:
    To provide for accurate dosimetry in a 137Cs irradiator, the following were investigated: (1) correct mapping of the irradiator cavity's dose distribution, (2) rotated versus stationary dose rate measurements, (3) exposure-to-dose calibration selection for exposure time calculation, and (4) irradiator-timer error correction. This work introduces techniques to map dose distributions and measure dose rates with new high-sensitivity radiochromic films and a small-volume ion chamber constructed for in-beam, high-intensity gamma irradiation. Measured film distributions were compared to manufacturer-provided data and independent measurements from an ion chamber and TLD-100 chips. Measured film distributions agreed with the manufacturer-provided data in the central-vertical region, but disagreed by as much as 95% in surrounding regions. The independent measurements agreed within 96% with the measured dose distribution. Dose rates varied by approximately 11% for a rotational versus stationary setup, by approximately 10% for the dose-to-medium correction between air and soft tissue, and by approximately 4-12% for irradiation times from 0.2-0.7 min due to timer error. In conclusion, a critical irradiator characterization should be performed, initially, as a part of the acceptance testing of a newly installed irradiator, and periodically as an ongoing quality assurance protocol. We investigated, and recommend as part of a comprehensive irradiator verification protocol, the inclusion of radiochromic film-measured dose distributions, dose rates measured during rotation when samples are likewise rotated for exposure, timer error corrections for short-time irradiation, and exposure-to-dose corrections that reflect typical sample compositions, e.g., soft tissue or air.

    Keywords:
    Animals • Cesium Radioisotopes • Gamma Rays • Humans • Radiometry • Radiotherapy • Thermoluminescent Dosimetry • instrumentation • instrumentation* • methods* • standards • statistics & numerical data • therapeutic use • therapeutic use*


Duke University * Pratt * Deans * Staff * Faculty * Reload * Login
x