| Publications [#61005] of Roger C. Barr
Papers Published
- Pollard, A.E. and Barr, R.C., Adaptive sampling of intracellular and extracellular cardiac potentials with the fan method,
Med. Biol. Eng. Comput. (UK), vol. 25 no. 3
(1987),
pp. 261 - 8
(last updated on 2007/04/12)
Abstract: Adaptive sampling with the fan algorithm selects samples with an irregular temporal spacing that specifies each waveform with the minimum number of samples required for a given maximum error or tolerance ϵ. The authors describe the performance of the fan as a function of tolerance on cardiac action potentials and electrograms simulated with the Beeler-Reuter model or measured directly from the heart, including examples showing signal quality, average sampling rate and intervals between samples. The results suggest that good quality measurements of action potentials and electrograms can be obtained with remarkably low average sampling rates
Keywords: bioelectric potentials;computerised signal processing;data compression;electrocardiography;medical diagnostic computing;
|